Structure that is calculated, not assumed
Every member we size is supported by a calculation we can produce on request, checked against the loading standard in force on the site. The result is a structure that is safe, that is economical in material, and that an approving authority will accept without a second submission.
What the appointment covers
Services are taken in whole or in part. A client who needs only one of the items below is welcome to appoint us for that item alone.
Scheme design and framing strategy
The structural arrangement settled early: grid, spans, framing material and depth zones, agreed with the architectural layout rather than imposed on it afterwards.
Foundations
Interpretation of the geotechnical report, then design of pad, strip, raft or piled foundations, together with underpinning and retaining where the site requires it.
Reinforced concrete
Slab, beam, column and core design, with reinforcement drawings and bar bending schedules issued in a form the steel fixer can work from directly.
Structural steel
Member sizing, connection design, member and bolt schedules, and drawings issued to a standard the fabricator can take into the workshop.
Masonry and timber
Loadbearing and infill masonry, lintels and reinforced block design, and timber framing, roof structures and floor systems.
Lateral design
Wind and seismic analysis, the selection and design of the lateral system, and the drift and stability checks that support it.
Existing structures
Condition appraisal, assessment of the load a structure will carry as built, and design of strengthening, remedial works and openings cut into what is already there.
Temporary works
Design and review of propping, excavation support and formwork arrangements, so that the sequence of construction is safe as well as the finished building.
Calculation and certification package
The calculation set, the design statement and the certification the approving authority requires, issued under the seal of a licensed professional.
What is issued, and in what form
A structural package comprises general arrangement drawings, reinforcement or fabrication drawings, schedules, and a calculation set bound and indexed so that any member can be traced from the drawing to the sheet on which it was designed.
Where a contractor proposes a change on site, it is assessed against the original calculation and either accepted in writing or refused with the reason given. Verbal approval of a structural change is not given.
Codes applied
Colombia: NSR-10. United Kingdom: the Eurocodes, with the United Kingdom National Annexes. United States: ASCE 7 for loading, ACI 318 for concrete and the AISC specification for steel. Trinidad and Tobago: the Small Building Code, with British and American standards applied where the Code is silent.
Seismic and wind parameters are taken from the hazard mapping that governs the site, and the basis of design is stated on the first sheet of the calculation set.
Send the layout and the ground conditions
Tell us where the site is and what you intend to build. We will set out the scope, the programme and the fee before any work begins.